NMIP Electrical Metrology Division

Introduction

Electrical Metrology Division of National Metrology Institute of Pakistan (NMIP) is mandated to disseminate and maintain National Standards for DC Voltage & Resistance, Current, Inductance, Capacitance, and Power. In addition to this, the Laboratory Quality Management System (LQMS) is being practiced to remain in accordance with and fulfill the requirements of ISO 17025.

Functions of EMD

  • Realizing the primary standards and maintaining the national/reference standards in the field of electrical measurements.
  • Maintaining the traceability of electrical standards through ILCs and bilateral arrangements with NMIs of other countries.
  • Improving and developing measurement techniques for test/calibration in the field of electrical metrology.
  • Providing test and calibration services to public/private industrial sectors, especially to defense organizations of the country.
  • Carrying out testing & standardization of electrical home appliances like PVC cables, electronics blasts, and vinyl tiles.
  • Providing training, consultancy, and advisory services to different public and private departments/organizations in the field of electrical metrology.
  • Conducting specific R & D work to develop and improve the in-use calibration techniques and supporting instrumentation in the field of electrical metrology.
  • Realizing and establishing primary standards of voltage through Josephson Voltage Standard (JVS) system for 1 Volt and 10 Volt.
  • Future Goals / Targets / Plans

  • Establishing facilities for on-site calibration to customers in the field of electrical metrology.
  • Enhancing electrical measurement capabilities and facilities regarding range & accuracy for:
  • AC/DC Voltage: Up to 50 kV
  • AC/DC Current: Up to 100 A
  • Improving existing measurement techniques including uncertainty budget in the field of electrical measurement.
  • Visiting local industries to understand their problems related to trade and offering expertise.
  • Providing in-house training for metrologists on calibration techniques under BMR Project provisions.
  • Enhancing the range and accuracy of parameters in the accredited scope related to Electrical Metrology.
  • Participating in national/international ILC and key comparison in electrical parameters organized by concerned metrology bodies and NMIs.
  • Training metrologists on improved calibration techniques from NMIs in the Asia Pacific Region and developed countries.
  • Collaborating with other NMIs and metrology institutes for expert visits and the latest calibration techniques.
  • PNAC Accredited Calibration Facilities

    Parameter Range Uncertainty
    DC Voltage 0 - 1200 V ±3 x 10-4
    AC Voltage 0-1050 Volts (10 HZ-1.5 MHz) ± 0.01 %
    DC Current 0-20 Amps, 20-1000 Amps (with Coils) ± 0.14 % / ± 0.015%
    AC Current 0-20 Amps (10 Hz-30KHz), 20-1000 A (with Coils) ± 0.05 % / ± 0.07 %
    Resistance 0 ?-100 K?, 100 k?-1M?, 1 M?-400M? ± 1 PPM- -8PPM / ± 16PPM / ± 0.02%
    Inductance 1µH-100 H ± 0.03 %
    Power (DC / AC) 1 mW-20 KW ± 0.03 % (DC)